UL規格 UL 61010-1 3rd Edition, 2023: UL Standard for Safety Electrical Equipment For Measurement, Control, and Laboratory Use; Part 1: General Requirements (Includes all amendments and changes through Revision Page(s))

UL規格 61010-1 3rd Edition, 2023

産業規格・仕様書  >  UL  > 




UL規格 61010-1 3rd Edition, 2023

326,480(税込)

数量

書名

UL 61010-1 3rd Edition, 2023: UL Standard for Safety Electrical Equipment For Measurement,
Control, and Laboratory Use; Part 1: General Requirements
(Includes all amendments and changes through Revision Page(s))
UL規格 61010-1, 第3版, 2023: 測定,制御及び試験室用電気機器の安全性 パート1: 一般要求事項
発行元 UL
発行年/月 2023年6月   
装丁 ペーパー
ページ数 216 ページ
発送予定 海外倉庫よりお取り寄せ 1-2週間以内に発送します
※当ウェブ・ショップに掲載のない規格につきましては、別途お問合せ下さいませ。
※掲載の規格は、当ウェブ・ショップに掲載時点で確認できた最新版でございます。
最新の発行状況につきましては受注時に改めて確認をさせて頂きますので予めご了承下さい。


 

Description

This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of their publications for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51.

This part of IEC 61010 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used.

a) Electrical test and measurement equipment

This is equipment which by electromagnetic means tests, measures, indicates or records one or more electrical or physical quantities, also non-measuring equipment such as signal generators, measurement standards, power supplies for laboratory use, transducers, transmitters, etc.

NOTE 1 This includes bench-top power supplies intended to aid a testing or measuring operation on another piece of equipment. Power supplies intended to power equipment are within the scope of IEC 61558 (see 1.1.2 h)).

This standard also applies to test equipment integrated into manufacturing processes and intended for testing manufactured devices.

NOTE 2 Manufacturing test equipment is likely to be installed adjacent to and interconnected with industrial machinery in this application.

b) Electrical industrial process-control equipment

This is equipment which controls one or more output quantities to specific values, with each value determined by manual setting, by local or remote programming, or by one or more input variables.

c) Electrical laboratory equipment

This is equipment which measures, indicates, monitors, inspects or analyses materials, or is used to prepare materials, and includes in vitro diagnostic (IVD) equipment.

This equipment may also be used in areas other than laboratories; examples include self-test IVD equipment to be used in the home and inspection equipment to be used to check people or material during transportation.

Equipment excluded from scope

This standard does not apply to equipment within the scope of:
a) IEC 60065 (Audio, video and similar electronic apparatus);
b) IEC 60204 (Safety of machinery – Electrical equipment of machines);
c) IEC 60335 (Household and similar electrical appliances);
d) IEC 60364 (Electrical installations of buildings);
e) IEC 60439 (Low-voltage switchgear and controlgear assemblies);
f) IEC 60601 (Medical electrical equipment);
g) IEC 60950 (Information technology equipment including electrical business equipment, except as specified in 1.1.3);
h) IEC 61558 (Power transformers, power supply units and similar);
i) IEC 61010-031 (Hand-held probe assemblies);
j) IEC 61243-3 (Live working – Voltage detectors – Part 3: Two-pole low-voltage type).

kDV) IEC 62368-1 (Audio/Video, Information and Communication Technology Equipment – Part 1: Safety Requirements).
lDV) UL/ULC 1389 Plant Oil Extraction Equipment and Systems.

Computing equipment

This standard applies only to computers, processors, etc. which form part of equipment within the scope of this standard or are designed for use exclusively with the equipment.

NOTE Computing devices and similar equipment within the scope of IEC 62368-1 and conforming to its requirements are considered to be suitable for use with equipment within the scope of this standard. However, some of the requirements of IEC 62368-1 for resistance to moisture and liquids are less stringent than those in this standard (see 5.4.4 second paragraph)).

This standard applies to equipment:
a) To be employed in accordance with ANSI/NFPA 70, National Electrical Code® (NEC);
b) Designed to comply with the general requirements of CAN/CSA C22.2 No. 0 and to be installed in accordance with the Canadian Electrical Code (CEC), Part I, CSA C22.1; or
c) Both (a) and (b).

Gas, vapor and voltage detectors or sensors

Equipment intended to measure, sense or detect one or more electrical or physical quantities that identify an imminent hazard and used for signalling, may use this standard only when no alternative standard exists.

Note 1 This standard is considered not to apply to gas detectors and similar equipment within the scope of ANSI/UL 2034, ANSI/UL 2075, CSA C22.2 No. 205, or ULC-S588.
Note 2 Examples of standards providing additional safety requirements for gas or vapor detectors or sensors, which can be used in conjunction with this standard, are ANSI/UL 60079-29-1, ANSI/UL 920001, ANSI/UL 920004, CSA C22.2 No. 60079-29-1, or CSA C22.2 No. 62990-1.
Note 3 Clause 1.2.1 specifies the use of Clause 17 to assess conformity for hazards or environments not fully covered in Clauses 6 to 16, including aspects not covered by this document in Clause 1.2.2.
Note 4 Local and national codes may have additional requirements based on the end products’ intended use.
Note 5 This standard is considered not to apply to voltage detectors and similar equipment within the scope of UL 1436, CAN/ULC 61243 series, or CSA C22.2 No 160.