IEC規格 CSA IEC 61000-4-2 2nd Edition, 2012(R2022): Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test

IEC規格 CSA IEC 61000-4-2, 2012(R2022)

産業規格・仕様書  >  IEC  > 

産業規格・仕様書  >  CSA  > 




IEC規格 CSA IEC 61000-4-2, 2012(R2022)

69,850(税込)

数量

書名

CSA IEC 61000-4-2 2nd Edition, 2012(R2022): Electromagnetic compatibility (EMC) - Part 4-2:
Testing and measurement techniques - Electrostatic discharge immunity test

IEC規格 CSA IEC 61000, Part 4-2 第2版, 2012 (R2022)電磁両立性(EMC):
パート4-2 試験および測定技術 静電放電イミュニティ試験
発行元 CSA Group (CSA)
発行年/月 2012年6月
装丁 ペーパー
ページ数 154 ページ
発送予定 海外倉庫よりお取り寄せ 1-2週間以内に発送します
※セキュアPDF版をご希望のお客様は別途お問合せ下さいませ。
※当ウェブ・ショップに掲載のない規格につきましては、別途お問合せ下さいませ。
※掲載の規格は、当ウェブ・ショップに掲載時点で確認できた最新版でございます。 最新の発行状況につきましては受注時に改めて確認をさせて頂きますので予めご了承下さい。


 

Description

This part of IEC 61000 relates to the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and from personnel to adjacent objects. It additionally defines ranges of test levels which relate to different environmental and installation conditions and establishes test procedures.

The object of this standard is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. In addition, it includes electrostatic discharges which may occur from personnel to objects near vital equipment.

This standard defines:

- typical waveform of the discharge current;
- range of test levels;
- test equipment;
- test setup;
- test procedure;
- calibration procedure;
- measurement uncertainty.

This standard gives specifications for test performed in "laboratories" and "post-installation tests" performed on equipment in the final installation.

This standard does not intend to specify the tests to be applied to particular apparatus or systems. Its main aim is to give a general basic reference to all concerned product committees of the IEC. The product committees (or users and manufacturers of equipment) remain responsible for the appropriate choice of the tests and the severity level to be applied to their equipment.

In order not to impede the task of coordination and standardization, the product committees or users and manufacturers are strongly recommended to consider (in their future work or revision of old standards) the adoption of the relevant immunity tests specified in this standard.