NEMA規格 ANSI/NEMA 250, 2020 Edition: Enclosures for Electrical Equipment

NEMA規格 ANSI/NEMA 250, 2020 Edition

産業規格・仕様書  >  NEMA  > 




NEMA規格 ANSI/NEMA 250, 2020 Edition

48,950(税込)

数量

書名

NEMA 250, 2020 Edition: Enclosures for Electrical Equipment (1000 Volts Maximum)
NEMA規格 ANSI/NEMA 250, 2020年版: 電気機器用エンクロージャ
発行元 National Electrical Manufacturers Association (NEMA)
発行年/月 2020年1月   
装丁 ペーパー
ページ数 63 ページ
発送予定 海外倉庫よりお取り寄せ 2週間以内に発送します
※セキュアPDF版 (シングルユーザー), セキュアPDF版 + 冊子版をご希望のお客様は別途お問合せ下さいませ。
※当ウェブ・ショップに掲載のない規格につきましては、別途お問合せ下さいませ。
※掲載の規格は、当ウェブ・ショップに掲載時点で確認できた最新版でございます。 最新の発行状況につきましては受注時に改めて確認をさせて頂きますので予めご了承下さい。


 

Description

This Standard covers enclosures for electrical equipment rated not more than 1000 Volts and intended to be installed and used as follows:

- a. enclosures for indoor locations, Types 1, 2, 5, 12, 12K, and 13; and
- b. enclosures for indoor or outdoor locations, Types 3, 3X, 3R, 3RX, 3S, 3SX, 4, 4X, 6, and 6P; and
- c. enclosures for hazardous (classified) locations Types 7 and 9

This Standard covers the requirements to provide protection to the enclosed equipment against specific environmental conditions. The requirements of this Standard mandate that enclosures and equipment shall be installed and used in accordance with manufacturer’s instructions and 110.3(B) of the ANSI/NFPA 70, National Electrical CodeR (NECR).

This Standard covers the requirements for enclosures that are installed and ready for use in nonhazardous (unclassified) locations.

This Standard additionally covers the requirements for dust-tight enclosures that are installed and ready for use where permitted by NECR in Class II, Division 2; Class III, Division 1; Class III, Division 2; and Zone 22 hazardous (classified) locations as defined by the NECR, or by ANSI/UL 121201, Nonincendive Electrical Equipment for use in Class I and II, Division 2, and Class III, Divisions 1 and 2 Hazardous (Classified) Locations (UL 121201). Where dust-tight enclosures are integral to or incorporate separable electrical connections (e.g., plug and receptacle, plug and connector body, inlet and connector body) for use in Class II, Division 2; Class III, Division 1; Class III, Division 2; and Zone 22 hazardous (classified) locations, the combination shall be designed to ensure that current cannot be ruptured at the separable electrical connections while energized parts are exposed.

This Standard also references requirements for Class I; Division 1 explosion-proof enclosures marked Type 7 and Class II, Division 1 dust-ignition-proof enclosures marked Type 9. The reference requirements are in accordance with ANSI/UL 1203 ExplosionProof and Dust-IgnitionProof Electrical Equipment for Use in Hazardous (Classified) Locations (UL 1203) with the associated area classifications and installation requirements in accordance with NECR.

This Standard supplements the requirements for enclosures that are contained in the individual product Standards.

This Standard does not cover the requirements for the protection of the enclosed equipment against conditions such as condensation, gas vapor ignition, thermal damage, icing, corrosion, or contamination, which may occur within the enclosure or which may enter via conduit or unsealed openings.

This Standard does not cover protection of personnel from contact with enclosed electrical equipment where the enclosures or equipment are incompletely installed or where enclosed electrical equipment has been rendered accessible for servicing, maintenance, testing, troubleshooting, internal measurements, or calibration or by damage.

A product that contains features, characteristics, components, materials, or systems new or different from those in use when the Standard was developed, and that involves a risk of fire, electric shock, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements as determined necessary to maintain the level of safety for the user of the product as originally anticipated by the intent of this Standard.