IEC規格 60904-7, 4th Edition, 2019: Photovoltaic devices - Part 7: Computation of the spectral mismatch correction for measurements of photovoltaic devices

IEC規格 60904-7, 4th Edition, 2019

産業規格・仕様書  >  IEC  > 




IEC規格 60904-7, 4th Edition, 2019

22,550(税込)

数量

書名

IEC 60904-7, 4th Edition, 2019: Photovoltaic devices - Part 7: Computation of the spectral mismatch
correction for measurements of photovoltaic devices

IEC規格60904-7, 第4版, 2019: 太陽光発電デバイス: パート 7: 光電装置の測定に対する
スペクトル不整合修正の演算
発行元 International Electrotechnical Commission (IEC)
発行年/月 2019年8月   
装丁 ペーパー
ページ数 26 ページ
発送予定 海外倉庫よりお取り寄せ 2週間以内に発送します
※PDF版 (シングルユーザー)をご希望のお客様は別途お問合せ下さいませ。
※当ウェブ・ショップに掲載のない規格につきましては、別途お問合せ下さいませ。
※掲載の規格は、当ウェブ・ショップに掲載時点で確認できた最新版でございます。 最新の発行状況につきましては受注時に改めて確認をさせて頂きますので予めご了承下さい。


 

Description

This part of IEC 60904 describes the procedure for correcting the spectral mismatch error introduced in the testing of a photovoltaic device, caused by the mismatch between the test spectrum and the reference spectrum (e.g. AM1.5 spectrum) and by the mismatch between the spectral responsivities (SR) of the reference device and of the device under test and therewith reduce the systematic uncertainty. This procedure is valid for single-junction devices but the principle may be extended to cover multi-junction devices.

The purpose of this document is to give guidelines for the correction of the spectral mismatch error, should there be a spectral mismatch between the test spectrum and the reference spectrum as well as between the reference device SR and the device under test SR. The calculated spectral mismatch correction is only valid for the specific combination of test and reference devices measured with a particular test spectrum.

Since a PV device has a wavelength-dependent spectral responsivity, its performance is significantly affected by the spectral distribution of the incident radiation, which in natural sunlight varies with several factors such as location, weather, time of year, time of day, orientation of the receiving surface, etc., and with a solar simulator varies with its type and conditions. If the irradiance is measured with a thermopile-type radiometer (that is not spectrally selective) or with a PV reference device (IEC 60904-2), the spectral irradiance distribution of the incoming light must be known to make the necessary corrections to obtain the performance of the PV device under the reference spectral irradiance distribution defined in IEC 60904-3.

If a reference PV device or a thermopile type detector is used to measure the irradiance, then, following the procedure given in this document, it is possible to calculate the spectral mismatch correction necessary to obtain the short-circuit current of the device under test under the reference spectral irradiance distribution in IEC 60904-3 or any other reference spectrum. If the reference PV device has the same relative spectral responsivity as the device under test then the reference device automatically takes into account deviations of the measured spectral irradiance distribution from the reference spectral irradiance distribution, and no further correction of spectral mismatch errors is necessary. In this case, location and weather conditions are not critical when the reference device method is used for performance measurements under natural sunlight. Also, for identical relative SRs, the spectral classification of the simulator is not critical for measurements with solar simulators.

If the performance of a PV device is measured using a known spectral irradiance distribution, its short-circuit current at any other spectral irradiance distribution can be computed using the spectral responsivity of the PV device under test.